063-2599552

info@mpttech.co.th

Back Pressure Relief Valve

Applications

Steam & Water Analysis Systems

Grab Sampling Systems

Benefits

Large area diaphragm design to keep upstream pressure stable

Features

Wetted parts in SS316 and Viton*

Fixed regulated pressure at 1.5 barg

Fluid: Liquid

Downloads

Compact Conditioning Panel

Applications

Conditioning sample for SWAS Systems

Benefits

Built to plug and play

It allows multiple configurations according to the needs of the client

Constant flow and pressure assured in analyzers

Valid for analyzer systems and manual sampling

Expandable: Customizable with incorporation of Specific conductivity,cation conductivity,pH and

Dissolved oxygen analyzers in one panel

Features

Built according ASME PTC-19.11

Wetted parts:316 stainless steel

Pressure and temperature ratings 240 barg @ 540 C (3480,9 psi(g) @1004 F)(higher on request)

Sample ow up to 100 L/h(21,9 gal/h)(higher on request)

Downloads

Degassed Cation Conductivity

Applications

Degassed measurement in Steam Water

Analysis Systems

Benefits
Include atmospheric pressure sensor to set the temperature at boiler point

Designed to install the cationic resin column, the transmitter and the conductivity

Probes in the same plate

Short time to reach the degassed conductivity measurement

Including all necessary components as a complete unit,just piping,plug-in and ready to use

Features
According with ASTM D4519

Provide with necessary shell protection to prevent operators from hot injury

Compact wall mount design

CE marking

Flow indication

Switch protection “ no flow ”

Downloads

High Pressure Reducer Valve

Applications

Steam & Water Analysis Systems

Boiler water Blowdown systems

Grab Sampling Systems

 

Benefits
Avoid obstructions

Higher flow rate

According ASME-PTC 19.11.

 

Features

Rod-in-Tube Design

Designed for High Pressure up to 350(5076 psig) barg

Design Temperature:150 C (302 F)

Outlet pressure 1 to 20 barg. (14,5 to 290 psig)

Downloads

Multi-Streams Analyzer Sequencer

Applications

Analyzer Systems

Benefits

Compact equipment, it occupies minimal space

Manifold block with common drainage (avoid installed drainage tubing from each sample)

Avoid installing tube from rotamer to manifold block

Block manifold with ninimum capacity

No dead legs

No contamination samples

Features

Control up to eight streams and two analyzers

Compact wall mount design

Flow indication

Contionuous sample flow in all lines

No delays in measurement

Enclosure rating: IP65/NEMA 4X

CE marking

Downloads

Sample cooler

Applications

Steam & Water Analysis Systems

Point of use cooling / sampling

Grab Sampling Systems

 

Benefits

Dual helical coil design, providing maximum heat exchange area

Compact design minimizes cooling water needs

Removable outer Shell enclosure, providing easy maintenance and clean

No welded parts in sample tubing, Pass through fittings

 

Features

Highest efficiency sample coole commercially available

Exotic materials, such as titanium, Inconel and Hastelloy on the tube side and Monel, cipronickel and stainless steel on the shell side are available

 

Downloads

Thermal Shut-Off Valve

Aplications

Steam & Water Sampling Systems

Automatic themostatic bypass

Thermostartic flow control

High or low temperature relief

High temperature safety shut-off

Thermostatic drain valve

Thermostatic cooling water control

Thermostatic condensate drain

Heat exchangers

 

Bebefits

Automatically resets, no  operator involvement required

No outside power source required

Rugged compact design easy installation fast response

Maintenance free

Delivers superior value vs. more expensive electriv valves

 

Features

Operating temperatures unaffected by pressure.

Corrosion resistant; all stainless steel 316L construction

Dry contact for remote alarm indication (optional)

Downloads